Active CUI Control & Diagnostics System

Dual-Purpose Flow Management: Automated Inspection, Purging, and Drainage

                       [Dry Air Inlet]
                              │ (Main supply via 10mm distribution line)
                              ▼
           ┌──────────────────────────────────────┐
           │   VCI POWER Dry Air Control Panel    │
           │   - Regulated Pressure: 0.01-0.05 MPa │
           │   - Rated Flow Rate: 500 L/min       │
           └──────────────────────────────────────┘
                              │
             ┌────────────────┴────────────────┐
             ▼                                 ▼
   [Inspect Plug Ports]               [Automated PPS Drain Plugs]
(Dedicated Top/Side Inlets)        (Spaced at a Max of 3m intervals)
             │                                 │
             └───────────────┬─────────────────┘
                             ▼
             ┌─────────────────────────────────┐
             │ 316L / PTFE Perforated Tubes    │
             │ (Injects Dry Air / N2 / VCI)    │
             └─────────────────────────────────┘
                             │
                             ▼
             ┌─────────────────────────────────┐
             │  Continuous 6mm Annular Air Gap  │
             │ (Evaporates Moisture & Purges)  │
             └─────────────────────────────────┘

The fluidic architecture functions as a balanced, low-pressure micro-climate circuit. It utilizes the "VCI POWER Dry Air" manifold unit—equipped with a 4-stage inline filter/regulator block measuring 190mm × 200mm—to feed dual-purpose boundary ports.

  1. Ultra-Low Pressure Injection Parameters: The manifold introduces air at a regulated design pressure of 0.01 - 0.05 MPa (0.1 to 0.5 bar) with a robust rated flow capacity of 500 L/min. The dual terminal manifold connects directly to a 10mm distribution pipe network. This low injection pressure ensures rapid fluid velocity inside the 17mm diameter, 100mm long micro-perforated channels while keeping the pressure in the open 6mm insulation air gap safely near atmospheric levels to protect the delicate weather jacket.
  2. Interchangeable Injection and Flow Path Routing: Fluid injection is fully versatile. Gaseous nitrogen (\(N_{2}\)), dried air, or vapor inhibitors can be introduced from either the upper Inspect Plugs or right through the lower PPS Automated Drain Plugs.
  3. Fully Automated, High-Density Fluid Drainage (Max 3m Intervals): To prevent "trapped water pockets" caused by gravity or thermal barriers, PPS Automated Drain Plugs are positioned at a maximum interval of 3 meters. When liquid water builds up at support rings or bottom-most sections, the automated valve discharges the water safely out of the weather cladding. Concurrently, the 500 L/min dry air stream uses these same open ports to vent vapor-laden air, creating a continuous, unidirectional drying sweep.